{"product_id":"tigo-ts4-x-o-800w-module-level-optimizer-monitoring-rapid-shutdown","title":"Tigo TS4-X-O – 800W Module-Level Optimizer, Monitoring \u0026 Rapid Shutdown","description":"\u003cp data-end=\"335\" data-start=\"238\"\u003e\u003cstrong data-end=\"335\" data-start=\"238\"\u003eTigo TS4-X-O – 800W Module-Level Optimizer, Monitoring \u0026amp; Rapid Shutdown (MC4, 0.6\/1.2M Cable)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"755\" data-start=\"337\"\u003eThe \u003cstrong data-end=\"357\" data-start=\"341\"\u003eTigo TS4-X-O\u003c\/strong\u003e is a powerful \u003cstrong data-end=\"413\" data-start=\"372\"\u003emodule-level power electronics (MLPE)\u003c\/strong\u003e solution that combines \u003cstrong data-end=\"485\" data-start=\"437\"\u003eoptimization, monitoring, and rapid shutdown\u003c\/strong\u003e in one compact unit. Designed for today’s high-power PV modules, this version supports up to \u003cstrong data-end=\"587\" data-start=\"579\"\u003e800W\u003c\/strong\u003e, \u003cstrong data-end=\"600\" data-start=\"589\"\u003e25A Isc\u003c\/strong\u003e, and \u003cstrong data-end=\"630\" data-start=\"606\"\u003e1500V UL \/ 1000V IEC\u003c\/strong\u003e, making it ideal for modern residential, commercial, and retrofit solar installations.\u003c\/p\u003e\n\u003cp data-end=\"1076\" data-start=\"757\"\u003eTigo’s patented technology helps maximize energy production by reducing the effects of \u003cstrong data-end=\"911\" data-start=\"844\"\u003emodule mismatch, partial shading, and uneven string performance\u003c\/strong\u003e, while also improving system safety and providing full module-level visibility when paired with the required Tigo accessories.\u003c\/p\u003e\n\u003ch3 data-end=\"1096\" data-start=\"1078\" data-section-id=\"1sboupi\"\u003eKey Features\u003c\/h3\u003e\n\u003cp data-end=\"1928\" data-start=\"1098\"\u003e✔ \u003cstrong data-end=\"1129\" data-start=\"1100\"\u003eModule-level optimization\u003c\/strong\u003e for improved energy harvest \u003cbr data-end=\"1198\" data-start=\"1195\"\u003e✔ \u003cstrong data-end=\"1227\" data-start=\"1200\"\u003eModule-level monitoring\u003c\/strong\u003e for detailed system visibility \u003cbr data-end=\"1299\" data-start=\"1296\"\u003e✔ \u003cstrong data-end=\"1330\" data-start=\"1301\"\u003eRapid shutdown capability\u003c\/strong\u003e for enhanced safety and code compliance \u003cbr data-end=\"1411\" data-start=\"1408\"\u003e✔ Supports modules up to \u003cstrong data-end=\"1444\" data-start=\"1436\"\u003e800W\u003c\/strong\u003e \u003cbr data-end=\"1485\" data-start=\"1482\"\u003e✔ Rated for \u003cstrong data-end=\"1518\" data-start=\"1497\"\u003e20A Imp \/ 25A Isc\u003c\/strong\u003e \u003cbr data-end=\"1559\" data-start=\"1556\"\u003e✔ Compatible with \u003cstrong data-end=\"1601\" data-start=\"1577\"\u003e1500V UL \/ 1000V IEC\u003c\/strong\u003e systems \u003cbr data-is-only-node=\"\" data-end=\"1650\" data-start=\"1647\"\u003e✔ \u003cstrong data-end=\"1689\" data-start=\"1652\"\u003eSimple snap-on frame installation\u003c\/strong\u003e or mounting to racking \u003cbr data-end=\"1753\" data-start=\"1750\"\u003e✔ Works with thousands of inverter models from \u003cstrong data-end=\"1823\" data-start=\"1800\"\u003e50+ inverter brands\u003c\/strong\u003e \u003cbr data-end=\"1864\" data-start=\"1861\"\u003e✔ \u003cstrong data-end=\"1886\" data-start=\"1866\"\u003e25-year warranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-end=\"1961\" data-start=\"1930\" data-section-id=\"1u4pz52\"\u003eElectrical Specifications\u003c\/h3\u003e\n\u003cul data-end=\"2624\" data-start=\"1963\"\u003e\n\u003cli data-end=\"2037\" data-start=\"1963\" data-section-id=\"10s5jc8\"\u003e\n\u003cstrong data-end=\"1990\" data-start=\"1965\"\u003eMaximum output power:\u003c\/strong\u003e 800W\u003c\/li\u003e\n\u003cli data-end=\"2124\" data-start=\"2038\" data-section-id=\"12zmb47\"\u003e\n\u003cstrong data-end=\"2072\" data-start=\"2040\"\u003eMaximum current (Imp \/ Isc):\u003c\/strong\u003e 20A \/ 25A\u003c\/li\u003e\n\u003cli data-end=\"2208\" data-start=\"2125\" data-section-id=\"1hkapnk\"\u003e\n\u003cstrong data-end=\"2157\" data-start=\"2127\"\u003eInput voltage range (Vmp):\u003c\/strong\u003e 12 – 80V\u003c\/li\u003e\n\u003cli data-end=\"2283\" data-start=\"2209\" data-section-id=\"hf974d\"\u003e\n\u003cstrong data-end=\"2237\" data-start=\"2211\"\u003eMaximum input voltage:\u003c\/strong\u003e 80V\u003c\/li\u003e\n\u003cli data-end=\"2397\" data-start=\"2284\" data-section-id=\"y5gtoh\"\u003e\n\u003cstrong data-end=\"2313\" data-start=\"2286\"\u003eMaximum system voltage:\u003c\/strong\u003e 1500V UL \/ 1000V IEC for this MC4 version\u003c\/li\u003e\n\u003cli data-end=\"2473\" data-start=\"2398\" data-section-id=\"yk8h4i\"\u003e\n\u003cstrong data-end=\"2427\" data-start=\"2400\"\u003eMaximum output current:\u003c\/strong\u003e 20A\u003c\/li\u003e\n\u003cli data-end=\"2547\" data-start=\"2474\" data-section-id=\"chajql\"\u003e\n\u003cstrong data-end=\"2499\" data-start=\"2476\"\u003eMaximum efficiency:\u003c\/strong\u003e 99.6%\u003c\/li\u003e\n\u003cli data-end=\"2624\" data-start=\"2548\" data-section-id=\"ekvjp6\"\u003e\n\u003cstrong data-end=\"2578\" data-start=\"2550\"\u003eRecommended fuse rating:\u003c\/strong\u003e 30A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"2671\" data-start=\"2626\" data-section-id=\"jbcczn\"\u003ePhysical \u0026amp; Environmental Specifications\u003c\/h3\u003e\n\u003cul data-end=\"3176\" data-start=\"2673\"\u003e\n\u003cli data-end=\"2764\" data-start=\"2673\" data-section-id=\"5pbfvo\"\u003e\n\u003cstrong data-end=\"2708\" data-start=\"2675\"\u003eCable lengths (input\/output):\u003c\/strong\u003e 0.6 m \/ 1.2 m\u003c\/li\u003e\n\u003cli data-end=\"2828\" data-start=\"2765\" data-section-id=\"1mifb6t\"\u003e\n\u003cstrong data-end=\"2782\" data-start=\"2767\"\u003eConnectors:\u003c\/strong\u003e MC4\u003c\/li\u003e\n\u003cli data-end=\"2933\" data-start=\"2829\" data-section-id=\"18frjqx\"\u003e\n\u003cstrong data-end=\"2846\" data-start=\"2831\"\u003eDimensions:\u003c\/strong\u003e 5.4 × 5.5 × 0.9 in (139.7 × 138.4 × 22.9 mm)\u003c\/li\u003e\n\u003cli data-end=\"3005\" data-start=\"2934\" data-section-id=\"q28bxn\"\u003e\n\u003cstrong data-end=\"2947\" data-start=\"2936\"\u003eWeight:\u003c\/strong\u003e 1.15 lb (520 g)\u003c\/li\u003e\n\u003cli data-end=\"3107\" data-start=\"3006\" data-section-id=\"1me0gsu\"\u003e\n\u003cstrong data-end=\"3034\" data-start=\"3008\"\u003eOperating temperature:\u003c\/strong\u003e -40°F to 185°F (-40°C to 85°C)\u003c\/li\u003e\n\u003cli data-end=\"3176\" data-start=\"3108\" data-section-id=\"1kukwg7\"\u003e\n\u003cstrong data-end=\"3129\" data-start=\"3110\"\u003eOutdoor rating:\u003c\/strong\u003e IP68\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-end=\"3198\" data-start=\"3178\" data-section-id=\"8ypr0w\"\u003eImportant Note\u003c\/h3\u003e\n\u003cp data-end=\"3474\" data-start=\"3200\"\u003eFor \u003cstrong data-end=\"3250\" data-start=\"3204\"\u003erapid shutdown and module-level monitoring\u003c\/strong\u003e, the \u003cstrong data-end=\"3283\" data-start=\"3256\"\u003eTigo Access Point (TAP)\u003c\/strong\u003e and \u003cstrong data-end=\"3320\" data-start=\"3288\"\u003eCloud Connect Advanced (CCA)\u003c\/strong\u003e are required. An optional \u003cstrong data-end=\"3366\" data-start=\"3347\"\u003eRSS Transmitter\u003c\/strong\u003e can be used for enhanced multi-factor rapid shutdown functionality.\u003c\/p\u003e\n\u003cp data-end=\"3663\" data-start=\"3476\"\u003eThe \u003cstrong data-end=\"3496\" data-start=\"3480\"\u003eTigo TS4-X-O\u003c\/strong\u003e is an excellent choice for installers looking to add \u003cstrong data-end=\"3590\" data-start=\"3550\"\u003eoptimization, safety, and visibility\u003c\/strong\u003e to high-power module systems without sacrificing inverter compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003ca style=\"display: inline-block; background: #c62828; color: #ffffff; padding: 12px 20px; border-radius: 8px; text-decoration: none; font-weight: 600; font-family: Arial,Helvetica,sans-serif;\" rel=\"noopener noreferrer\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0664\/7676\/9517\/files\/682e43ada4501a338ea12111_002-00203-00_1.1_Datasheet_TS4-X-O_20250429_-_EN.pdf?v=1776358178\" target=\"_blank\"\u003e Download Datasheet (PDF) \u003c\/a\u003e\u003c\/p\u003e","brand":"Mann Solar Store","offers":[{"title":"Default Title","offer_id":49789660365037,"sku":null,"price":72.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0664\/7676\/9517\/files\/Captura_ead88f05-333c-4626-ae45-f73a18f6d8e9.jpg?v=1776358518","url":"https:\/\/mannsolar.com\/products\/tigo-ts4-x-o-800w-module-level-optimizer-monitoring-rapid-shutdown","provider":"Mann Solar Store","version":"1.0","type":"link"}